Successful mitral valve-in-ring repair of mitral annuloplasty ring dehiscence causing severe mitral regurgitation: a case report.
Sharma, Harish ; Nadir, M Adnan ; Steeds, Richard P ; Doshi, Sagar N
Sharma, Harish
Nadir, M Adnan
Steeds, Richard P
Doshi, Sagar N
Citations
Altmetric:
Affiliation
Other Contributors
Publication date
2021-10-26
Subject
Collections
Research Projects
Organizational Units
Journal Issue
Abstract
Background: Annuloplasty failure caused by ring dehiscence can lead to trans-ring and para-ring mitral regurgitation (MR). Transcatheter treatments are available for patients at prohibitive risk of surgery. In patients unsuitable for edge-to-edge repair, valve-in-ring (ViR) transcatheter mitral valve (MV) implantation has been described to treat trans-ring or para-ring jets but not both concurrently.
Case summary: A 78-year-old male presented with severe MR due to dehiscence of a 34 mm Edwards Physio II mitral annuloplasty ring. Transoesophageal echocardiography showed two jets of regurgitation; trans-ring and para-ring. Repair was successfully undertaken with a ViR procedure (29 mm S3 Edwards Lifesciences).
Discussion: Patients with failure of MV annuloplasty with trans-ring and para-ring regurgitation can be safely and effectively treated by ViR transcatheter MV implantation.
Citation
Sharma H, Nadir MA, Steeds RP, Doshi SN. Successful mitral valve-in-ring repair of mitral annuloplasty ring dehiscence causing severe mitral regurgitation: a case report. Eur Heart J Case Rep. 2021 Oct 26;5(11):ytab433. doi: 10.1093/ehjcr/ytab433