Myocardial fibrosis predicts ventricular arrhythmias and sudden death after cardiac electronic device implantation.
Leyva, Francisco ; Zegard, Abbasin ; Okafor, Osita ; Foley, Paul ; Umar, Fraz ; Taylor, Robin J ; Marshall, Howard ; Stegemann, Berthold ; Moody, William ; Steeds, Richard P ... show 5 more
Leyva, Francisco
Zegard, Abbasin
Okafor, Osita
Foley, Paul
Umar, Fraz
Taylor, Robin J
Marshall, Howard
Stegemann, Berthold
Moody, William
Steeds, Richard P
Citations
Altmetric:
Affiliation
Other Contributors
Publication date
2022-02-22
Subject
Collections
Research Projects
Organizational Units
Journal Issue
Abstract
Background: Increasing evidence supports a link between myocardial fibrosis (MF) and ventricular arrhythmias.
Objectives: The purpose of this study was to determine whether presence of myocardial fibrosis on visual assessment (MFVA) and gray zone fibrosis (GZF) mass predicts sudden cardiac death (SCD) and ventricular fibrillation/sustained ventricular tachycardia after cardiac implantable electronic device (CIED) implantation.
Methods: In this prospective study, total fibrosis and GZF mass, quantified using cardiovascular magnetic resonance, was assessed in relation to the primary endpoint of SCD and the secondary, arrhythmic endpoint of SCD or ventricular arrhythmias after CIED implantation.
Results: Among 700 patients (age 68.0 ± 12.0 years), 27 (3.85%) experienced a SCD and 121 (17.3%) met the arrhythmic endpoint over median 6.93 years (IQR: 5.82-9.32 years). MFVA predicted SCD (HR: 26.3; 95% CI: 3.7-3,337; negative predictive value: 100%). In competing risk analyses, MFVA also predicted the arrhythmic endpoint (subdistribution HR: 19.9; 95% CI: 6.4-61.9; negative predictive value: 98.6%). Compared with no MFVA, a GZF mass measured with the 5SD method (GZF5SD) >17 g was associated with highest risk of SCD (HR: 44.6; 95% CI: 6.12-5,685) and the arrhythmic endpoint (subdistribution HR: 30.3; 95% CI: 9.6-95.8). Adding GZF5SD mass to MFVA led to reclassification of 39% for SCD and 50.2% for the arrhythmic endpoint. In contrast, LVEF did not predict either endpoint.
Conclusions: In CIED recipients, MFVA excluded patients at risk of SCD and virtually excluded ventricular arrhythmias. Quantified GZF5SD mass added predictive value in relation to SCD and the arrhythmic endpoint.
Citation
Leyva F, Zegard A, Okafor O, Foley P, Umar F, Taylor RJ, Marshall H, Stegemann B, Moody W, Steeds RP, Halliday BP, Hammersley DJ, Jones RE, Prasad SK, Qiu T. Myocardial Fibrosis Predicts Ventricular Arrhythmias and Sudden Death After Cardiac Electronic Device Implantation. J Am Coll Cardiol. 2022 Feb 22;79(7):665-678. doi: 10.1016/j.jacc.2021.11.050
Type
Article