Publication

Systematic Review and Meta-Analysis of Studies Comparing the Rate of Post-operative Periprosthetic Fracture Following Hip Arthroplasty With a Polished Taper Slip versus Composite Beam Stem

Mabrouk, Ahmed
Mahmood, Ansar
West, Robert
Pandit, Hemant
Feathers, Jacob R.
Lamb, Jonathan N.
Citations
Altmetric:
Affiliation
Other Contributors
Publication date
2023-06-19
Research Projects
Organizational Units
Journal Issue
Abstract
Background: We compared the incidence of postoperative periprosthetic femoral fractures (POPFF) following hip arthroplasty with either a cemented polished taper slip (PTS) stem or a cemented composite beam (CB) stem in comparative studies. Methods: A systematic review of comparative studies, written in English and published in peer-reviewed journals since the year 2000, was conducted. Study quality was assessed using the Newcastle-Ottawa scale.The overall study qualities were good. There were 913,021 patients from 18 cohorts included in the meta-analysis. There were 294,540 patients who received a CB stem and 618,481 received a PTS stem. Cohorts were classified as high- or low-risk for POPFF based on patient risk factors. A metanalysis was performed using a random effects model, and the relative incidence with 95% confidence intervals (CIs) was reported. Results: The patients at low risk of POPFF had an incidence rate ratio of 3.14 (CI: 2.48, 3.98) for the PTS group versus the CB group. Whereas, the patients at high risk of POPFF had an incidence rate ratio of 9.87 (CI: 3.63, 26.80) for the PTS group versus the CB group. Conclusions: The risk of POPFF is lower when hip arthroplasty was performed using a CB stem versus a PTS stem. This protective effect was greatest in patients who had a higher risk of POPFF. Surgeons should consider the effect of cemented stem choice on the risk of subsequent periprosthetic femur fracture, particularly in frail or elderly patients who are at a higher risk of postoperative periprosthetic femoral fracture.
Citation
Mabrouk A, Feathers JR, Mahmood A, West R, Pandit H, Lamb JN. Systematic Review and Meta-Analysis of Studies Comparing the Rate of Post-operative Periprosthetic Fracture Following Hip Arthroplasty With a Polished Taper Slip versus Composite Beam Stem. J Arthroplasty. 2024 Jan;39(1):269-275. doi: 10.1016/j.arth.2023.06.014. Epub 2023 Jun 19.
Type
Article
Description
Publisher
Embedded videos