Show simple item record

dc.contributor.authorHussein, Mohsin
dc.contributor.authorJenko, Nathan
dc.contributor.authorMittal, Alok Kumar
dc.contributor.authorRaniga, Sameer
dc.contributor.authorIyengar, Karthikeyan P
dc.contributor.authorDjearaman, Madava
dc.contributor.authorBotchu, Rajesh
dc.date.accessioned2023-09-26T16:14:02Z
dc.date.available2023-09-26T16:14:02Z
dc.date.issued2023-08-04
dc.identifier.citationHussein M, Jenko N, Mittal AK, Raniga S, Iyengar KP, Djearaman M, Botchu R. Validation of the supinator fat pad sign in radial head and neck fractures. Emerg Radiol. 2023 Aug 4. doi: 10.1007/s10140-023-02163-4. Epub ahead of print. PMID: 37540298.en_US
dc.identifier.issn1070-3004
dc.identifier.eissn1438-1435
dc.identifier.doi10.1007/s10140-023-02163-4
dc.identifier.pmid37540298
dc.identifier.urihttp://hdl.handle.net/20.500.14200/2330
dc.description.abstractObjective: To assess the displacement of the supinator fat pad in radial head and neck fractures and to validate its significance. Material and methods: One hundred two adult patients from the Royal Orthopaedic Hospital, Birmingham, United Kingdom and Sultan Qaboos University Hospital, Muscat, Oman with confirmed radial head and/or neck fractures were included. Fractures were classified using the Mason-Johnston classification. The displacement of the supinator fat pad from the radius was measured on anterior-posterior (AP) and lateral radiographs and correlated to fracture classification. Results: The supinator fat pad was on average displaced by 10.6 mm and 13.8 mm from the radius on AP and lateral radiographs, respectively. The displacement of the fat pad progressively increased between non-displaced (Mason I) and severely comminuted (Mason III) fractures on both the AP (10.25 to 14.25 mm) and lateral (12.70 to 16.00 mm) projections. The progression of displacement on AP (p = 0.016) and on lateral (p = 0.007) projections was statistically significant. Fracture dislocation was not associated with increased fat pad displacement. Conclusion: The supinator fat pad sign is a useful adjunct in the assessment of radial head and neck fractures.en_US
dc.language.isoenen_US
dc.publisherSpringeren_US
dc.relation.urlhttps://link.springer.com/journal/10140en_US
dc.rights© 2023. The Author(s), under exclusive licence to American Society of Emergency Radiology (ASER).
dc.subjectOrthopaedicsen_US
dc.titleValidation of the supinator fat pad sign in radial head and neck fracturesen_US
dc.typeArticle
dc.source.journaltitleEmergency Radiology
dc.source.countryUnited States
rioxxterms.versionNAen_US
dc.contributor.trustauthorJenko, Nathan
dc.contributor.trustauthorDjearaman, Madava
dc.contributor.departmentImagingen_US
dc.contributor.roleAllied Health Professionalen_US
oa.grant.openaccessnaen_US


This item appears in the following Collection(s)

Show simple item record