Evaluation of diurnal and postural intracranial pressure employing telemetric monitoring in idiopathic intracranial hypertension.
Author
Mitchell, James LBuckham, Rebecca
Lyons, Hannah
Walker, Jessica K
Yiangou, Andreas
Sassani, Matilde
Thaller, Mark
Grech, Olivia
Alimajstorovic, Zerin
Julher, Marianne
Tsermoulas, Georgios
Brock, Kristian
Mollan, Susan P
Sinclair, Alexandra J
Publication date
2022-11-01
Metadata
Show full item recordAbstract
Objectives: Intracranial pressure (ICP) has been thought to vary diurnally. This study evaluates diurnal ICP measurements and quantifies changes in ICP occurring with changes in body posture in active idiopathic intracranial hypertension (IIH). Methods: This prospective observational study utilized telemetric ICP monitoring in people with active IIH. Participants had the Raumedic p-Tel ICP intraparenchymal device (Raumedic, Hembrechts, Germany) surgically inserted. Changes in ICP in the supine position were evaluated. Then, the ICP was measured in the standing, sitting, supine, left lateral decubitus positions and with coughing and bending. Ultimately, changes in ICP over the course of 24 h were recorded. ISRCTN registration number 12678718. Results: 15 women were included, mean (standard deviation) age 29.5 (9.5) years, body mass index 38.1 (6.2) kg/m2, and baseline mean ICP of 21.2 (4.8) mmHg (equivalent to 28.8 (6.5) cmCSF). Mean ICP rose with the duration in the supine position 1.2 (3.3) mmHg over 5-minutes (p = 0.175), 3.5 (2.8) mmHg over 30-minutes (p = 0.0002) and by a further 2.1 (2.2) mmHg over 3 h (p = 0.042). Mean ICP decreased by 51% when moving from the supine position to standing (21.2 (4.8) mmHg to 10.3 (3.7) mmHg respectively, p = 0.0001). Mean ICP increased by 13% moving from supine to the left lateral decubitus position (21.2 (4.8) mmHg to 24.0 (3.8) mmHg, p = 0.028). There was no significant difference in ICP measurements at any point during the daytime, or between 5-minute standing or supine recordings and prolonged ambulatory daytime and end of night supine recordings respectively. ICP, following an initial drop, increased progressively in conjunction with lying supine position from 23:00 h to 07:00 h by 34% (5.2 (1.9) mmHg, p = 0.026). Conclusion: This analysis demonstrated that ICP does not appear to have a diurnal variation in IIH, but varies by position and duration in the supine position. ICP rose at night whilst the patient was continuously supine. Furthermore, brief standing and supine ICP measures in the day predicted daytime prolonged ambulatory measures and end of night peak ICP respectively. This knowledge gives reassurance that ICP can be accurately measured and compared at any time of day in an ambulant IIH patient. These are useful findings to inform clinical measurements and in the interpretation of ICP analyses in IIH. Trial registration: ISTCRN (12678718).Citation
Mitchell JL, Buckham R, Lyons H, Walker JK, Yiangou A, Sassani M, Thaller M, Grech O, Alimajstorovic Z, Julher M, Tsermoulas G, Brock K, Mollan SP, Sinclair AJ. Evaluation of diurnal and postural intracranial pressure employing telemetric monitoring in idiopathic intracranial hypertension. Fluids Barriers CNS. 2022 Nov 1;19(1):85. doi: 10.1186/s12987-022-00384-2Type
ArticleAdditional Links
https://fluidsbarrierscns.biomedcentral.com/https://www.ncbi.nlm.nih.gov/pmc/journals/1454/
PMID
36320018Journal
Fluids and Barriers of the CNSPublisher
BMCae974a485f413a2113503eed53cd6c53
10.1186/s12987-022-00384-2