Global Ring Study to Investigate the Comparability of Total Assay Performance of Commercial Claudin 18 Antibodies for Evaluation in Gastric Cancer
Name:
Publisher version
View Source
Access full-text PDFOpen Access
View Source
Check access options
Check access options
Author
Jasani, BharatTaniere, Philippe
Schildhaus, Hans-Ulrich
Blighe, Kevin
Parry, Suzanne
Wilkinson, Dawn
Atkey, Neil
Clare-Antony, Scott
McCabe, Clare
Quinn, Christine
Dodson, Andrew
Publication date
2023-11-08
Metadata
Show full item recordAbstract
Claudin 18.2 (CLDN18.2), the dominant isoform of CLDN18 in gastric tissues, is a highly specific tight junction protein of the gastric mucosa with variably retained expressions in gastric and gastroesophageal junction cancers. Additionally, CLDN18.2-targeted treatment with zolbetuximab, in combination with chemotherapy, has recently been assessed in 2 phase-III studies of patients with HER2-negative, locally advanced, unresectable, or metastatic gastric or gastroesophageal junction adenocarcinoma. These trials used the investigational VENTANA CLDN18 (43-14A) RxDx immunohistochemistry (IHC) assay on the Ventana BenchMark platform to identify patients eligible for CLDN18.2-targeted treatment. We report the findings of a global ring study evaluating the analytical comparability of concordance of the results of 3 CLDN18 antibodies (Ventana, LSBio, and Novus) stained on 3 IHC-staining platforms (Ventana, Dako, and Leica). A tissue microarray (TMA), comprising 15 gastric cancer cases, was stained by 27 laboratories across 11 countries. Each laboratory stained the TMAs using at least 2 of the 3 evaluated CLDN18 antibodies. Stained TMAs were assessed and scored using an agreed IHC-scoring algorithm, and the results were collated for statistical analysis. The data confirmed a high level of concordance for the VENTANA CLDN18 (43-14A; Ventana platform only) and LSBio antibodies on both the Dako and Leica platforms, with accuracy, precision, sensitivity, and specificity rates all reaching a minimum acceptable ≥85% threshold and good-to-excellent levels of concordance as measured by Cohen's kappa coefficient. The Novus antibody showed the highest level of variability against the reference central laboratory results for the same antibody/platform combinations. It also failed to meet the threshold for accuracy and sensitivity when used on either the Dako or Leica platform. These results demonstrated the reliability of IHC testing for CLDN18 expression in gastric tumor samples when using commercially available platforms with an appropriate methodology and primary antibody selection.Citation
Jasani B, Taniere P, Schildhaus HU, Blighe K, Parry S, Wilkinson D, Atkey N, Clare-Antony S, McCabe C, Quinn C; CLDN Study Group; Dodson A. Global Ring Study to Investigate the Comparability of Total Assay Performance of Commercial Claudin 18 Antibodies for Evaluation in Gastric Cancer. Lab Invest. 2024 Jan;104(1):100284. doi: 10.1016/j.labinv.2023.100284. Epub 2023 Nov 8.Type
ArticlePMID
37949357Journal
Laboratory InvestigationPublisher
Elsevierae974a485f413a2113503eed53cd6c53
10.1016/j.labinv.2023.100284