• Login
    View Item 
    •   Home
    • Sandwell and West Birmingham NHS Trust
    • Medicine and Emergency Care
    • Cardiology
    • Research (Articles)
    • View Item
    •   Home
    • Sandwell and West Birmingham NHS Trust
    • Medicine and Emergency Care
    • Cardiology
    • Research (Articles)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of West Midlands Evidence RepositoryCommunitiesAuthorsTitlesPublication DateSubjectsPublication TypesJournalPublisherThis CollectionAuthorsTitlesPublication DateSubjectsPublication TypesJournalPublisherProfilesView

    My Account

    LoginRegister

    About

    AboutPolicies Privacy NoticeBlack Country Healthcare NHS Foundation TrustCoventry and Warwickshire Partnership NHS TrustDudley Group NHS Foundation TrustGeorge Eliot Hospital NHS TrustSandwell and West Birmingham NHS TrustSouth Warwickshire University NHS Foundation TrustUniversity Hospitals Birmingham NHS Foundation TrustUniversity Hospitals Coventry and Warwickshire NHS TrustWalsall Healthcare NHS Trust

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Retinal vascular dynamics : a window for observing an irregular heartbeat. A case report

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Author
    Heitmar, Rebekka
    Kirchhoff, Paulus
    Blann, Andrew cc
    Kotliar, Konstantin
    Affiliation
    University of Huddersfield; Sandwell and West Birmingham NHS Trust; Aachen University of Applied Sciences
    Publication date
    2024-01-19
    Subject
    Cardiology
    
    Metadata
    Show full item record
    Abstract
    Objective: We aimed to characterize several aspects of retinal vascular dynamics in a patient with arrythmia in order to elicit additional diagnostic information on microvascular dysfunction. Methods: A 68-year-old male patient with arrythmia and an age- and gender-matched control subject underwent ocular examination including dynamic retinal vessel assessment with flicker light provocation. Retinal vessel diameters were measured continuously following a standard protocol (IMEDOS Systems, Jena, Germany). The data were evaluated using methods of signal analysis. Results: Retinal vessel response following flicker provocation as well as local structural and functional behavior of retinal vessels were comparable between both individuals. The arrhythmia case demonstrated irregular arterial and venous heart rate (HR) pulsation with an average frequency of 1 Hz. Moreover, the case showed a higher magnitude and larger periods of low-frequency retinal vessel oscillations as well as lower periodicity of both HR pulsations and low-frequency vasomotions. Conclusions: Besides numerical examination of irregular HR pulsations in case of arrhythmia, from the direct noninvasive assessment of retinal vessel dynamics one can derive more detailed information on microvascular function including the whole spectrum of retinal arterial and venous pulsations and vasomotions. This may have implications for health screening not limited to atrial fibrillation.
    Citation
    Heitmar R, Kirchhoff P, Blann A, Kotliar K. Retinal vascular dynamics: A window for observing an irregular heartbeat. A case report. Microcirculation. 2024 Jan 19:e12844. doi: 10.1111/micc.12844
    Type
    Article
    Handle
    http://hdl.handle.net/20.500.14200/3502
    DOI
    10.1111/micc.12844
    PMID
    38241091
    Journal
    Microcirculation
    Publisher
    Wiley
    ae974a485f413a2113503eed53cd6c53
    10.1111/micc.12844
    Scopus Count
    Collections
    Research (Articles)

    entitlement

    DSpace software (copyright © 2002 - 2025)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.