• Login
    View Item 
    •   Home
    • Sandwell and West Birmingham NHS Trust
    • Surgical Services
    • Trauma and Orthopaedics
    • Research (Articles)
    • View Item
    •   Home
    • Sandwell and West Birmingham NHS Trust
    • Surgical Services
    • Trauma and Orthopaedics
    • Research (Articles)
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Browse

    All of West Midlands Evidence RepositoryCommunitiesAuthorsTitlesPublication DateSubjectsPublication TypesJournalPublisherThis CollectionAuthorsTitlesPublication DateSubjectsPublication TypesJournalPublisherProfilesView

    My Account

    LoginRegister

    About

    AboutPolicies Privacy NoticeBlack Country Healthcare NHS Foundation TrustCoventry and Warwickshire Partnership NHS TrustDudley Group NHS Foundation TrustGeorge Eliot Hospital NHS TrustSandwell and West Birmingham NHS TrustSouth Warwickshire University NHS Foundation TrustUniversity Hospitals Birmingham NHS Foundation TrustUniversity Hospitals Coventry and Warwickshire NHS TrustWalsall Healthcare NHS Trust

    Statistics

    Most Popular ItemsStatistics by CountryMost Popular Authors

    Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity

    • CSV
    • RefMan
    • EndNote
    • BibTex
    • RefWorks
    Author
    Bruce, Angus
    De, Chiranjit
    Golmohamad, Ramez
    Habeebullah, Awais
    Sikand, Manoj
    Gulati, Aashish
    Affiliation
    Epsom & St Helier University Hospitals NHS Trust; The Royal Orthopaedic Hospital NHS Foundation Trust; Sandwell and West Birmingham NHS Trust
    Publication date
    2021-08-23
    Subject
    Orthopaedics
    
    Metadata
    Show full item record
    Abstract
    Aim Hip fracture fixation surgeries are one of the most common surgeries that every trauma unit does regularly. Surgical training and expertise to fix these fractures properly are quite crucial for every orthopaedic surgeon. Therefore, orthopaedic training programmes all over the world consider significant focus on this and teach trainee surgeons expectantly to manage these fractures independently. Surgical fixation of hip fractures often requires fluoroscopy assistance in the operating theatre with associated hazards from ionising radiation. Moreover, hip fractures can be sometimes quite complex and may require relatively more fluoroscopy usage even with the higher grade of the operating surgeons. Therefore, training need for hip fracture fixation surgery is imperative and there is also a need for intraoperative radiation safety. This study has tried to find a balance between intraoperative fluoroscopic radiation exposure, surgical training requirement, and hip fracture complexity. Methodology This single centre study has collected retrospective peri-operative data over a period of two years including hip fractures that required fluoroscopy-guided surgical fixation. Femoral head fractures, subtrochanteric fractures, diaphyseal fractures, and trochanteric fractures with associated pelvic fractures were excluded from the study. We collected data on demographic parameters, fracture complexity and grading (Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Trauma Association [AO/OTA] Classification), intraoperative ionising radiation exposure (centi-Gray/cm2), and grade of the operating surgeon in order to find any relation between these factors. Results Total 268 patients were included in the study with a mean age of 81.8 years (SD 9.3) comprising of 83 (31%) male patients and 185 (69%) female patients. The study population was further stratified into three groups depending upon the operating grade of the surgeon: ‘Junior Trainee’ (<five years of experience; 77 cases [29%]); ‘Senior Trainee’ (>five years of experience; 148 cases [55%]); and ‘Consultant’ (fully trained to practice independently; 43 cases [16%]). There was no statistically significant difference among these three sub-groups with regards to the age (p = 0.79), gender (p = 0.73), body mass index (p = 0.46), and fracture pattern (p = 0.96) of the patients. However, consultants tend to operate more on the higher American Society of Anesthesiologists (ASA) grade patients (p = 0.049) with more comorbidities. There was statistically significant higher fluoroscopic radiation exposure while junior trainee surgeons (p = 0.005) were operating and during the higher complex grade of hip fracture (p = <0.001) fixation. Conclusion In conclusion, the quantity of intra-operative radiation dose utilised in the surgical fixation of hip fractures is significantly associated with the grade and level of training of the operating surgeon and fracture complexity type. The results of this study emphasise and support the importance of comprehensive, supervised, and structured orthopaedic training for in-theatre radiation safety. It is recommended to have a safe balance between teaching, learning, and prevention of ionising radiation hazards in order to optimally achieve trainee’s professional development with successful patient outcomes.
    Citation
    Bruce A, De C, Golmohamad R, et al. (August 23, 2021) Intraoperative Fluoroscopic Radiation Exposure During Hip Fracture Fixation: A Study Combining Surgical Experience and Fracture Complexity. Cureus 13(8): e17393. doi:10.7759/cureus.17393
    Type
    Article
    Handle
    http://hdl.handle.net/20.500.14200/6006
    Journal
    Cureus
    Publisher
    Springer
    Collections
    Research (Articles)

    entitlement

    DSpace software (copyright © 2002 - 2025)  DuraSpace
    Quick Guide | Contact Us
    Open Repository is a service operated by 
    Atmire NV
     

    Export search results

    The export option will allow you to export the current search results of the entered query to a file. Different formats are available for download. To export the items, click on the button corresponding with the preferred download format.

    By default, clicking on the export buttons will result in a download of the allowed maximum amount of items.

    To select a subset of the search results, click "Selective Export" button and make a selection of the items you want to export. The amount of items that can be exported at once is similarly restricted as the full export.

    After making a selection, click one of the export format buttons. The amount of items that will be exported is indicated in the bubble next to export format.